aquakin.heating_energy#
- aquakin.heating_energy(t, Q_feed, T_feed_C, T_target_C=35.0, rho=1000.0, cp=4.186)[source]#
Digester sludge-heating energy (kWh/d) per Gernaey et al. 2014.
Energy to raise the digester feed from
T_feed_CtoT_target_C:Heatpower [kW] = (T_target − T_feed) × Q_feed × rho × cp / 86400 HE [kWh/d] = 24 × time-average(Heatpower)
with water density
rho(kg/m³) and specific heatcp(kJ/kg·°C). Temperatures are in Celsius. A feed already above the target contributes negative heating (no cooling credit is taken here; the OCI applies the methane offset separately).- Parameters:
Q_feed ((n_t,) digester feed flow (m³/d).)
T_feed_C ((n_t,) or scalar feed temperature (°C).)
t (Array)
T_target_C (float)
rho (float)
cp (float)
- Returns:
Digester sludge-heating energy in kWh/d, time-averaged over
t.- Return type:
float