aquakin.pumping_energy#
- aquakin.pumping_energy(t, Q_internal, Q_ras, Q_was)[source]#
Pumping energy (kWh/d) per Copp 2002 eq.
PE = (1 / T) × ∫ (0.004 × Q_internal + 0.008 × Q_ras + 0.05 × Q_was) dt
- Returns:
Pumping energy in kWh/d, time-averaged over
t.- Return type:
float
- Parameters:
t (Array)
Q_internal (Array)
Q_ras (Array)
Q_was (Array)