aquakin.aeration_energy#
- aquakin.aeration_energy(t, kla_history, volumes, saturation=8.0)[source]#
Aeration energy (kWh/d) per Copp 2002 eq.
AE = (S_sat / (T × 1.8 × 1000)) × ∫ Σ_i V_i × kLa_i(t) dt
- Parameters:
t ((n_t,) save times in days)
kla_history ((n_t, n_aerated_tanks) kLa value at each save time)
volumes ((n_aerated_tanks,) liquid volume of each aerated tank)
saturation (float) – Dissolved-oxygen saturation concentration (mg/L).
- Returns:
Aeration energy in kWh/d, time-averaged over
t.- Return type:
float