aquakin.pumping_energy#

aquakin.pumping_energy(t, Q_internal, Q_ras, Q_was)[source]#

Pumping energy (kWh/d) per Copp 2002 eq.

PE = (1 / T) × ∫ (0.004 × Q_internal + 0.008 × Q_ras + 0.05 × Q_was) dt

Returns:

Pumping energy in kWh/d, time-averaged over t.

Return type:

float

Parameters:
  • t (Array)

  • Q_internal (Array)

  • Q_ras (Array)

  • Q_was (Array)